STLRAMSCFL.COM

STLRAMSCFL.COM

Apc pdu guide

 

 

APC PDU GUIDE >> DOWNLOAD LINK

 


APC PDU GUIDE >> READ ONLINE

 

 

 

 

 

 

 

 











 

 

The APC by Schneider Electric Metered Rack Power Distribution Unit (PDU) may be used as a stand-alone, network-manageable power distribution device or up to four devices can be connected together using one network connection. The Rack PDU provides real-time remote monitoring of connected loads. User-defined alarms warn of potential circuit 2 Metered Rack PDU User's Guide Types of User Accounts The Rack PDU has three levels of access (Administrator, Device User, and Read-Only User), which are protected by user name and password requirements. • An Administrator can use all of the menus in the Web interface and all of the commands in the command line interface. Switched Rack PDU must be running firmware version 2.7.0 for the AOS firmware module and 2.7.3 for the application firmware module. Rack PDUs required You can use the command line interface only with APC Switched Rack PDUs. Exporting an .ini File You can configure all parameters of a Switched Rack PDU (including those for which there are not NetShelter Rack PDUs Our standard PDUs with industry-leading reliability, manageability, and security. Ideal for small and medium sized businesses, small-to-medium data centers, and edge computing. Basic Rack PDUs • Reliable power distribution Metered Rack PDUs • Real-time monitoring of connected loads The APC ® Switched Rack Power Distribution Unit (PDU) is a stand-alone, network-manageable device that allows programmable control of eight, sixteen, or twenty-four power outlets (depending on the model). You can control a PDU remotely through its Web, control console (serial or telnet), or SNMP interfaces. Contents hide 1 APC Rack Power Distribution Unit Installation Guide 2 General Information 3 Additional Resources 4 Inventory 5 Safety 6 Installation 6.1 Attach the cord retention trays 7 Attach cords to the tray 8 Vertical Mounting 8.1 C Toolless mounting: 9 Brackets: 10 Mounting the Rack PDU in a third-party enclosure 11 Horizontal Mounting … Continue reading "APC Rack Power Distribution 1 Switched Rack PDU User Guide Introduction Product Features The APC by Schneider Electric Switched Rack Power Distribution Unit (PDU) may be used as a stand-alone, network-manageable power distribution device or up to 4 devices can be connected together with one network connection. The Rack PDU provides real-time remote monitoring of connected The Command Line Interface (CLI) for American Power Conversion (APC ®) Switched Rack PDUs enables you to create scripts for automated operation. The existing text-based control console interface to Switched Rack PDUs is difficult to use for scripting because it is menu-driven. APC will support both interfaces. The CLI is not supported by APC. APC Rack Mount PDU, Metered-by-Outlet with Switching, 100V-120V/30A, (24) Outlets, 0U Vertical Rackmount (AP8632) Input Voltage: 120 V AC Features: Power Rating:2.88 kVA Form Factor:Rack-mountable Vertical Product Type:PDU Color:Black Power Rating:2.88 kVA Form Factor:Rack-mountable Vertical Input Receptacles:NEMA L5-30P Product Name:Metered-by-Outlet with Switching Rack PDU Output Receptacles The APC PDU service monitors the phase status of the user-specified phase (circuit) and reports the low/medium/high thresholds for that sensor, as dictated by the PDU. Service Type. SNMP. Instances on a Device. 3. Supported Systems/Applications. Any APC PDU device that supports the PowerNet392 SNMP MIB. Device Class. 2 apc.com Life is On | Schneider Electric| 3 Introduction APCTM by Schneider Electric offers a wide

Comment

You need to be a member of STLRAMSCFL.COM to add comments!

Join STLRAMSCFL.COM

© 2024   Created by STLRAMSCFL.COM.   Powered by

Badges  |  Report an Issue  |  Terms of Service