IEEE 400 : 2012. GUIDE FOR FIELD TESTING AND EVALUATION OF THE INSULATION OF SHIELDED POWER CABLES SYSTEMS RATED 5 KV AND ABOVE. BS EN 62271-201:2014 (published 2014-07) High-voltage switchgear and controlgear AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV. IEEE Std 400.2 -2013. IEEE Std 400.2 -2013 IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF) (less than 1 Hz) Sponsor Insulated Conductors Committee of the IEEE Power and Energy Society Approved 6 March 2013 IEEE-SA Standards Board . Version 1.3 IEEE P802.3db 100 Gb/s, 200 Gb/s, and 400 Gb/s Short Reach Fiber Task Force - July 2022 IEEE 802.3 Plenary Page 8 WG Motion # Move that the IEEE P802.3 Working Group approve IEEE_802d3_to_T11-2_062822_draft1_redacted.pdf with editorial license granted to the Chair (or his appointed agent) as liaison IEEE Std. 400.2-2013. EEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF) (less than 1 Hz) Table 3 - VLF withstand test voltages for sinusoidal and cosine-rectangular waveforms (see note 1*) Note 1. If the operating voltage is a voltage class lower than the rated voltage of the cable, it is recommended IEEE 400.2-2013 This guide describes VLF withstand and other diagnostic tests and the measurements that are performed in the field on service-aged shielded medium and high-voltage cables rated 5 kV through 69 kV with extruded and laminated insulation. VLF test methods utilize ac signals at frequencies less than 1 Hz. The information and data that follows is taken directly from the IEEE 400.2-2013 Standard. IEEE Std. 400.2-2013 IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF) (less than 1 Hz) Table 3 - VLF withstand test voltages for sinusoidal and cosine-rectangular waveforms (see note 1) Table 1: IEEE 400.2 VLF Test Voltage Levels for Sinusoidal, Cosine-Rectangular. Voltage Peak values are shown in brackets for Cosine-Rectangular and Squarewave. Test Duration. The current IEEE recommendation for the duration of a VLF test is from 15 to 60 minutes. Industry experience justifies a minimum time of 30 minutes. The most common European IEEE 400-2012.pdf. Click the start the download. DOWNLOAD PDF . Report this file. Description Download IEEE 400-2012.pdf Free in pdf format. Account 40.77.167.44. Login. Register. Search. Search. About Us We believe everything in the internet must be free. So this tool was designed for free download documents from the internet. IEEE 400.2-2013 IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)(less than 1 Hz) standard by IEEE, 06/09/2013. View all product details Most Recent Track It. Language: Available Formats; Options Availability; Priced From ( in USD ) PDF Immediate download $104.00 IEEE 400 : 2012. GUIDE FOR FIELD TESTING AND EVALUATION OF THE INSULATION OF SHIELDED POWER CABLES SYSTEMS RATED 5 KV AND ABOVE. BS EN 62271-201:2014. High-voltage switchgear and controlgear AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV. IEEE 400-2-2013 pdf free downlaod - IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF). 5. Very low frequency (VLF) testing VLF testing methods utilize AC signals in the frequency range 02-21. Download Now. Most of people like. IEEE 400.2 : 2013 standard pdf online $ I
Added by STLRAMSCFL.COM
Added by STLRAMSCFL.COM
Added by STLRAMSCFL.COM
Added by STLRAMSCFL.COM
© 2024 Created by STLRAMSCFL.COM. Powered by
You need to be a member of STLRAMSCFL.COM to add comments!
Join STLRAMSCFL.COM